Heat Recovery Ventilation
A heat exchange ventilation system that uses a heat exchanger (Lossnay core) to perform temperature (sensible heat) exchange.
Centralized Ventilation Solution
One Lossnay unit provides 24-hour ventilation for the entire house, from living room and bedrooms to the bathroom. The heat recovery system provides fresh air at a comfortable air temperature. A sensible heat exchanger effectively reduces excess humidity in the winter.
- Heat Exchanger
- Whole-house Solution
- Air Purification
- Quiet Operation
- MELCloud Control
Vertical type centralized ventilation with sensible heat exchange for residential use.
Key features
Quiet Operation
Noise is one of the most common concerns for residential ventilation. Ultra quiet operation is achieved with the sirocco fan designed by Mitsubishi Electric. The balance between airflow and static pressure is optimized and the fan rotation is minimized, leading to low noise levels.
Air Purification
An optional filter removes NOx and PM2.5 and improves indoor air quality. They can be incorporated inside the unit without any filter box, which saves space.
*NOx: Nitrogen oxide, which includes nitric oxide (NO) and nitrogen dioxide (NO2).
*PM2.5: Airborne particulates that are 2.5μm or smaller in size.
Wi-Fi Control
MELCloud is a Cloud-based solution for controlling Lossnay units either locally or remotely by computer, tablet or smartphone via the Internet. It allows Lossnay operations to be checked and controlled via MELCloud from virtually anywhere and Internet connection is available. With MELCloud, the Lossnay system can be used much more easily and conveniently.
Energy efficiency
Under regulation (EU) No. 1254/2014, the VL-CZPVU series has the highest energy-saving performance in its class (ErP A+). It saves heating and cooling costs by minimizing the energy loss that occurs during ventilation.
Variable airflow control
The default fan speed value (Fan speed 1: 30%, Fan speed 2: 50%, Fan speed 3: 70%, and Fan speed 4: 100%) of both supply air and exhaust air can be adjusted flexibly. Within the range between 25% and 100%, airflow can be adjusted by 1% increments to satisfactorily meet the designed airflow rate.
External airflow control
The airflow from the Lossnay unit can be altered using 0-10V signals from the controllers, such as the humidity stat and CO2 sensor (field supply). The Lossnay unit is also connected to the light switch and can change to boost operation mode (input 220-240V). These devices are connected directly to the Lossnay unit, allowing automatic fan speed control according to bathroom occupation, CO2 level, and humidity level.
Automatic bypass mode
It is possible to switch between “Lossnay ventilation (with heat exchange)” and “Bypass ventilation (without heat exchange)” either manually or automatically. When outside air is cooler than indoor air in summer, the unit directly draws in outside air, bypassing the heat exchanger.
Wide operating temperature range
The VL-CZPVU series can operate at temperatures down to –15°C. With a pre-heater, it can operate at temperatures down to –25°C.
* In areas where outdoor air falls below –20°C, an electric shutter (locally supplied) is required in the OA duct in addition to the pre-heater.
* The OA temperature must be higher than –15°C to use the pre-heater.
MELCloud for Lossnay
MELCloud enables fast, easy remote control and monitoring of Lossnay units. Wireless computer connectivity and an Internet-connected mobile or fixed terminal are all that are needed. MELCloud can also be used to control room air conditioners and Ecodan heat pumps simultaneously.
Key Control and Monitoring Features
- Turn system on/off
- Switching airflow & operating mode (Heat recovery / Bypass)
- Confirming the status of the filter/core (Maintenance notification)